0.1μm Hydrophilic PVDF Syringe Filters for Mycoplasma Filtration Sterile Individually Packed

In stock
Part No. SFPVH-1013S
Regular price $76.00 USD
Diameter
Pore Size
Package
Loading locations...
*International Shipping within 8 Business Days
*Customers are responsible for any import duties or taxes
*Read our Shipping Policy and Refund Policy
*Not for medical use

Cobetter sterile PVDF syringe filters are individually packed and made of both single-layer and double-layer hydrophilic PVDF membranes. For double-layer syringe filters, the first layer is a prefilter with a larger pore size which makes the syringe filter achieve high throughput. This construction prevents the build-up of back pressure typically caused by the blocking of an unprotected membrane. The single-layer ones achieve a high flow rate.

The hydrophilic treatment PVDF membrane achieves both low protein binding and a fast flow rate simultaneously, making it suitable for applications where high protein recovery is desired. Suitable for filtration of protein solutions and mild organic solutions.

The housing is made of premium polypropylene which has a wide chemical compatibility. The over molded design ensures higher operating pressures. Luer lock inlet/outlet offers a leak-tight syringe connection.

Features

  • 13, 25 and 33 mm diameter syringe filters
  • Double-layer membrane with graduated pore size for excellent loading capacity with fast flow rate
  • Exceptionally low protein binding
  • Broad chemical compatibility but not resist strong alkali (pH range: 2-10)
  • Individually packed, Eliminates sample contamination

Application

  • Hydrophilic Polyvinylidene difluoride (PVDF) for biological solutions
  • Protein/ enzyme solutions
  • Mild organic solutions
  • Routine sample preparation
  • Environmental samples

Quality Standards

  • ISO 9001:2015 Quality Management System
  • Manufactured for use in conformance with cGMP
  • COA/COQ provided with shipment
  • Endotoxin <0.25 EU/mL (LAL test, Aqueous extraction), USP<85>

How to use a syringe filter?

Choose the right type of membrane material based on the properties of your sample. Be careful of the chemical compatibility to avoid extractables and leachables. Read this article about How to choose a syringe filter.

1. Load the sample into the syringe.

2. Attach the filter to the luer-lock of the syringe with a twisting motion. Make sure it is securely attached.

3. Filter the sample. Hold the syringe and filter vertically, and gently press the plunger to push the sample through the filter. Take care not to apply too much force or you may damage the filter.

4. Discard the used filter and repeat for the next sample.

Physical Properties Intended Use for Research Use Only
Filter Format Syringe Filter
Filter Color/Membrane Color Blue
Diameter 13mm - 0.72 cm²
25mm - 3.4 cm²
33mm - 4.5 cm²
Pore Size 0.1 μm
Pre-filter No
pH Range 2.0 – 10.0
Wettability Hydrophilic
Materials Membrane Material PVDF
Housing Material Polypropylene (PP)
Operating Conditions Max. Operating Pressure 13mm: 6 bar
25mm: 3 bar
33mm: 2 bar
Max. Operating Temperature 50 °C
Connection Inlet / Outlet Female luer lock inlet and male luer slip outlet
Sterility Delivery Condition Sterile
Sterilization Method Gamma irradiation
Package Pack Size Pack of 100
Packaging Individually blister packed

 

Select by Volume

Sample Volume Filter Diameter Filtration Area Hold-up Volume
< 10 mL 13 mm 0.72 cm² < 25 μl 
10 mL to 100 mL 25 mm 3.4 cm²  < 100 μl
100 mL to 200 mL 33 mm 4.5 cm²  < 125 μl

 

  • Chemical_Compatibility_Chart_for_Syringe_Filters Download
What materials and specifications are available for Cobetter syringe filters?

Available materials: Nylon/PES/PTFE/PVDF/MCE/CA/PP
Pore sizes: 0.1/0.22/0.45/0.8/1.0/1.2/3.0/5.0/10.0μm
Diameter: 13mm, 25mm, 33mm
Nonsterile: 100/PK
Sterile: Individally packed, 100/PK

Are Cobetter sterile syringe filters pyrogen-free?

Cobetter sterile syringe filters are pyrogen-free.

Are Cobetter syringe filters Luer inlet/outlet? Are they fully compatible with syringes?

Cobetter syringe filters are equipped with Luer inlet/outlet, which are manufactured in accordance with GB/T 1962, ensuring reliable compatibility with standard syringes.

Can Cobetter PVDF syringe filters withstand DMSO?

Cobetter PVDF syringe filters are not recommended for filtering pure DMSO.
For DMSO applications, PTFE syringe filters are recommended, as they can withstand DMSO filtration at room temperature.

Which kind of syringe filter is recommended for precious protein samples?

For valuable protein samples, sterile PVDF syringe filters are recommended.
They provide high protein recovery rates (over 90% and even 99.9%) across a wide range of proteins.

What are the features and advantages of Cobetter syringe filters?

Fast flow rate.
No extractables.
Batch-to-batch consistency ensures reproducible experimental results.

Does Cobetter have suitable solutions for high-throughput filtration?

For high-throughput filtration, Cobetter recommends PES (Polyethersulfone) 96-well filter plates.

What is the shelf life of Cobetter syringe filters?

The non-sterile syringe filter has a shelf life of 3 years, while the sterile syringe filter has a shelf life of 2 years.