Lifecube™ SA Single-Use Transfer Sets with STT Silicone Tubing and AC Aseptic Connector, 1 set/pk

In stock
Part No. SAL03033
Regular price $70.00 USD
Port1+Port2
Tubing Material
Length
Loading locations...
*Ships Out within 3 Weeks
*Customers are responsible for any import duties or taxes
*Read our Shipping Policy and Refund Policy
*Not for medical use

Cobetter Lifecube™ single-use tubing assemblies are used for interconnection of different unit operations in a wide range of applications. With our tubing assemblies, you can easily connect multiple containers, vessels and process lines in one system, minimizing the risk of cross-contamination, saving time and reducing costs. The extension set is available in a variety of tubing sizes and lengths to meet your fluid transfer needs.

The Lifemeta™ AC Single-use Aseptic Connectors are integrated into the filter sets, provide quick and easy sterile connections.

Features

  • Common connectors and tubing assembly available
  • Double-layer packaging, sterilized by 25~45 kGy gamma irradiation
  • Non-sterile packaging, autoclavable
  • Flexible customized solutions

Applications

  • Fluid transfer between Single-use and stainless steel system
  • Fluid Transfer between different types of connectors
  • Upstream and downstream system switching
  • PUPSIT system (Pre-Use and Post-Sterilization Integrity Test)
  • Connect and transfer of Single-use products from different brands
  • Temporary feeding and filtration, etc

Quality Standards

  • ISO 9001: 2015 Quality Management System
  • ISO 4.8 / ISO 7 cleanroom production
  • Manufactured for use in conformance with cGMP
  • Each product is integrity tested prior to release
  • COA/COQ provided with shipment
  • Validation documents are available upon request
  • TSE/BSE certificate available
Physical Properties Product Name Lifecube™ SA Single-Use Transfer Sets
Number of Ports 2
Filter Size Without Filter
Tube Type Extension Line
Tube Size 1/4" ID x 7/16" OD
3/8" ID x 5/8" OD
1/2" ID x 3/4" OD
Materials Tubing Material Silicone (Lifemeta™ STT)
Connector Material AC Aseptic Connector: Polysulfone (PSF)
EC Connector: Polysulfone (PSF)
TC Connector: Polypropylene (PP)
Ports Port 1 / Port 2 AC Aseptic Connector + ECS/ECM Male
AC Aseptic Connector + 3/4" or 1-1/2" TC
AC Aseptic Connector + AC Aseptic Connector
Regulatory Compliance Compliance USP <788> Particulate Matter
USP <87> Cytotoxicity
USP <88> Biological Reactivity
FDA Indirect Food Additives, 21 CFR 177-182
ADCF Materials
Bacterial Endotoxin Endotoxin Limit of WFI System<0.25 EU/mL with the Limulus Amebocyte Lysate (LAL), USP <85>
Sterility Delivery Condition Sterile
Sterilization Method Gamma irradiation at 25–45 kGy
Package Pack Size Pack of 1
Packaging Individually packed in double PE bag


  • Cobetter_Lifecube_SA_Single-Use_Assemblies_Catalog_250710 Download
Cobetter’s custom tubing assemblies are non-sterile, can customers sterilize it by themselves?

Yes, user can sterilize only the tubing assemblies and the connectors, excluding any bags.

When user sterilize the connectors and tubing, all ports should be opened, such as connector plugs and blind caps on clamps. After sterilization is completed, they can be connected and used.

Attention: You will need to add an additional cable tie to offset the leakage risk caused by the high-temperature deformation of the original cable tie after off-line sterilization.

Can Cobetter self-developed tubings be used for organic solvent solutions?

Both Pt-cured silicone tubing (STT, ST5P, ST8H) and TPE tubing (STF) are resistant to organic solvents. For certain solvent resistance, please refer to the chemical compatibility section in the validation guidelines.

Are the integrity testing of bags and tubings conducted together?

The pressure resistance of the bags and tubings is different. For the bag, we apply an air pressure of around 0.015 bar or 0.02 bar after clamping with bag clamps. After a certain period, we measure the pressure decay. The tubing and fittings can withstand pressure of up to approximately 2 bar, and we apply a pressure of 1.6 or 1.7 bar to measure the pressure decay.

How do the drawings correspond to the product packaging?

Each product shown on a drawing represents the product within one package. If separate packaging or simultaneous use of multiple products is required, they can be split/integrated into a single drawing.