Purcise SAF Sterilizing-Grade Bricap C Series Capsule Filters
Couldn't load pickup availability
*Read our Shipping Policy and Refund Policy
PES membrane with asymmetric pore size provides high dirt-holding capacity, realizing the combination of high throughput and high loading capacity.
Specifications
Materials | Membrane | Hydrophilic Polyethersulfone(PES) |
Support | Polypropylene(PP) | |
Core/Cage/End Cap | Polypropylene(PP) | |
Capsule Housing | Polypropylene(PP) | |
Capsule Vent O-rings | Silicone | |
Filtration Area | C01-180cm² C02-420cm² C03-660cm² |
|
Operating Conditions | Max. Operating Temperature | 80°C |
Max. Differential Pressure (Forward) | 0.55 MPa @25°C 0.10 MPa @80°C |
|
Max. Differential Pressure (Reverse) | 0.21 MPa @25°C |
|
Quality Standards | Integrity | 100% Integrity testing |
Traceability | Each filter with a unique serial number | |
QMS | ISO 9001:2015 | |
Sterility | Delivery Condition | Non-sterile |
Sterilization Method | Can be autoclaved 25 cycles for 30 minutes at 130°C (Can not be steam sterilized in-line) | |
Package | Pack Size | 1/pk |
Packaging | Double PE bag |
*Note: Cobetter also provides filters with different sterilization methods:
1. Gamma compatible filters: can be sterilized by gamma irradiation at 25-45 kGy or can be autoclaved 5 cycles for 60 minutes at 126 °C. (Can not be steamed in-line);
2. Pre-sterilized filters by gamma irradiation at 25-45 kGy (Gamma-sterilized products cannot be re-sterilized with gamma irradiation or steam sterilization);
3. Pre-sterilized filters by autoclaved for 30 minutes at 121°C (Packed in sterile breathable bags).
Features
- High loading and throughput
- Reliable retention of bacteria and particles
- Extensive chemical compatibility
Applications
- Buffer filtration, process fluids sterile filtration
- Pre-column/ultra-filtration protection
- Filtration of intermediate products/stock solutions
- Filtration of terminal products
Regulatory Compliance
- Effluent meets the USP<788> requirement of particulate matter in large volume injection.
- Component materials meet the criteria for a “Non-fiber-releasing filter”as defined in 21 CFR 210.3(b)(6).
- Retention of 10⁷ cfu/cm² Brevundimonas diminuta(ATCC 19146) according to ASTM F838.
- Aqueous extraction from a cartridge contains less than 0.25EU/ml as determined by Limulus Amebocyte Lysate (LAL), meeting requirements of USP<85>.
- Components meet the requirement of USP <87> In Vitro Biological Reactivity Test.
- Components meet the criteria of the USP <88> Biological Reactivity Test for Class V-121 °C plastics.
- Components meet the FDA indirect Food Additive requirements cited in 21 CFR177-182.
- Based on the current information from our suppliers, all components used in the manufacture of this product are animal-free.
*Contact us for more specification details.