Lifemeta™ STF Thermoplastic Elastomer Tubing for Fluid Transfer 5m/15m

In stock
Part No. STFL050N
Regular price $16.20 USD
Regular price $18.00 USD Sale price $16.20 USD
Diameter
Thickness
Length
*Bulk Order? Request a Quote for Big Savings Now
*Ships within 3 Business Days
*Read our Shipping Policy and Refund Policy

Cobetter Lifemeta™ STF TPE tubing is a high-performance flexible tube extruded from medical-grade thermoplastic elastomer (TPE) material, with excellent heat sealing and sterile welding performance. Its inner wall is smooth and low-flaking. The Lifemeta™ STF has demonstrated considerable welding compatibility and weldability in comparison to the leading TPE tubes in the market. Compared with traditional silicone and PVC tubes, this product has wide chemical compatibility and can maintain excellent physicochemical performance under various working conditions.

Specifications

Brand Tubing Brand Lifemeta™ STF
Physical Properties Color Translucent
Material Thermoplastic Elastomer(TPE)
Length 5m(16.4ft) / 15m(50ft)
Durometer Hardness (Shore A) 60 ± 5
Burst Strength 0.4 - 0.6 MPa
Tensile Strength 5.17-5.18 MPa
Elongation at Break 742-776 %
Vacuum Resistance >30 kPa
Temperature Range -50 °C to 140 °C
Biological Safety Endotoxins <0.25 EU/ml
Bio-compatibility Meet the requirement of USP<87> In Vitro Cytotoxicity Test;

Meet the criteria of the USP<88> Biological Reactivity Test for Class VI-121°C plastics
Sterilization Option Gamma-irradiation 25-45 kGy in a sterile package and can not be re-sterilized.
Autoclave(121°C) 25 cycles, 30min
Package Pack Size 1/pk
Delivery Condition Nonsterile
Packaging Coil packaged in double PE bag

Features

  • Sterile welding and heat sealing
  • Excellent low absorption and low binding
  • Lower permeability compared to silicone resin
  • Smooth inner wall, excellent fluidity
  • Outstanding tensile strength

Applications

  • Cell culture media and buffer preparation
  • Liquid sampling systems
  • Filtration processes
  • Sterile filling
  • Sterile disconnect and connection
  • Single-use tubing assemblies

Regulatory Compliance

  • Aqueous extraction contains < 0.25 EU/mL as determined by Amebocyte Lysate, USP <85>.
  • Meet the requirement of USP <87> In Vitro Biological Reactivity Test.
  • Meet the criteria of the USP <88> Biological Reactivity Test for Class VI plastics.
  • Products do not contain animal derived components and are free from TSE risk.
  • These products are manufactured in a facility which adheres to ISO™ 9001:2015 Practices.

Q: What's the application of STS platinum-cured silicone tubing?

Cobetter STS platinum-cured silicone tubing is designed to facilitate fluid transfer in many pharmaceutical and biopharmaceutical applications.

Q: How many internal diameters are available for platinum-cured tubings?

Cobetter STS platinum-cured silicone tubing is available in 7 different internal diameters ranging from 1/8" (3mm) to 3/4" (19mm).

Q: What's the sterility method?

Gamma irradiation and autoclave.

Q: Cobetter’s custom tubing assemblies are non-sterile, can customers sterilize it by themselves?

1. Yes, customers can sterilize only the tubing assemblies and the connectors, excluding any bags.

2. When customers sterilize the connectors and tubing, all ports should be opened, such as connector plugs and blind caps on clamps. After sterilization is completed, they can be connected and used.

3. Especially attention shall be taken that you will need to add an additional cable tie to offset the leakage risk caused by the high-temperature deformation of the original cable tie after off-line sterilization.

Q: What is the recommended length to be reserved for thermoplastic tubing for aseptic connection and aseptic sealing?

Cobetter's aseptic connection machine and aseptic sealing machine can achieve aseptic connection and disconnection in general environments. It is recommended to reserve a length of 15cm for each connection and disconnection.

Q: Can silicone tubing and pump tubing be used for organic solvent solutions?

Silicone tubing is not resistant to organic solvents.

For pump tubing, we need to confirm specific details of the process, such as pipe diameter, operating pressure, duration of use, and the acidity/alkalinity of the fluid being pumped. If organic solvents are involved, it is recommended not to choose silicone tubing and instead opt for pump tubing that is resistant to organic solvents.

Q: Will a single-use system that has been irradiated have any impact on the product? Can irradiation residues be detected in the irradiated items?

No. The irradiation dose is validated to ensure sterilization effectiveness. Moreover, the irradiation process only involves energy absorption and does not involve direct contact with the radiation source. Therefore, there are no issues of irradiation residues in the disposable system.

Q: Are the integrity testing of bags and tubings conducted together?

The pressure resistance of the bags and tubings is different. The bag can withstand a pressure of 0.02 kg. For the bag, we apply a gas pressure of around 0.015 bar or 0.02 bar after clamping with bag clamps. After a certain period, we measure the pressure decay. The tubing and fittings can withstand pressure of up to approximately 2 bar, and we apply a pressure of 1.6 or 1.7 bar to measure the pressure decay.

Q: How do the drawings correspond to the product packaging?