0.5mL Ultrafiltration Centrifugal Filter with Regenerated Cellulose RC Membrane 24/pk
Couldn't load pickup availability
*Read our Shipping Policy and Refund Policy
Cobetter Briscale centrifugal filter is ideal for the concentration of proteins and biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms. The vertical design and membrane surface area provide fast concentration time and rapid protein concentration for up to 80-fold concentration.
The centrifugal filter unit consists of a lid, a filter device and a centrifuge tube. Use a pipette to collect the concentrate from the filter device. The ultrafiltrate is collected in the centrifuge tube for further analysis.
Specifications
Dimensions | Effective membrane area | 0.6cm² |
Overall Length x Tube diameter | 53 x 12.5 mm | |
Materials | Membrane Material | Regenerated Cellulose (RC) |
Centrifuge Tube | PP | |
Ultrafiltration device | PS | |
Seals |
Silicone | |
Concentrator Capacity | Maximum Sample Volume(Fixed angle 45° rotor) | 0.5ml |
Final volume | 15-20uL | |
Max. Centrifuge Force |
14000g | |
Sterility | Delivery Condition |
Nonsterile |
Sterilization Method |
Not Recommended | |
Package | Pack Size | 24pcs |
Packaging | Individually packed in PE bag |
Features
- RC membrane achieves a high recovery rate of>90%
- Color-coded cap with different MWCO, volume graduation for easy detection and user-friendly
- Low-binding regenerated cellulose(RC) ultrafiltration membranes
- Broad chemical compatibility pH 1-14
- 80-fold concentration with vertical membranes
- Translucent housing and volume marker make sample monitoring effortless.
Applications
- Concentration and purification of nucleic acids, proteins such as antigens, antibodies, enzymes, etc and other biomolecules
- Desalting, buffer exchange
- Remove primers, adapters or molecular tags from the reaction mixture
- Purification of macromolecules in tissue culture extracts or cell lysates
How to choose Cobetter Centrifugal Filters?
To choose which type to use, determine the molecular weight (MW) of your macromolecule of interest, and select an ultrafiltration membrane with a molecular weight cut-off (MWCO) that is 2-3 times smaller than the MW of your macromolecule.
Filter MWCO | Target MW |
3 kDa | 6 kDa < MW < 30 kDa |
10 kDa | 30 kDa < MW < 100 kDa |
30 kDa | 100 kDa < MW < 200 kDa |
50 kDa | 200 kDa < MW < 500 kDa |
100 kDa | 500 kDa < MW |
Processing Time
Processing time of different MWCO filters.
Protein Recovery Rate
The RC membrane and smooth inner wall design have extremely low protein adsorption. Can achieve a recovery rate of more than 90%.
- Cobetter_Centrifugal_Filters_241106 Download